Shoremaster Compact 40 |
 PN 10550040 |
 |
- Voltage and frequency conversion
- High efficiency
- Modular design for high capacity, high redundancy and easy installation
- No problems with limited shore supply
- Pure sine wave output
- Ultra compact and low weight
- 100% galvanic isolation from shore
- High start-up power to counterbalance peak load
- Can be linked in parallel to increase power
- Can be upgraded for more output power
- No risk of corrosion
- Ready for central monitoring
- Clear LCD display with important information
- Low maintenance
- Marine grade design
|
Description
Living the high life on board a superyacht can require the generators to run twenty-four hours per day, something not always allowed in many harbours. However, the Shoremaster enables you to moor in the place of your choice and to connect to any local shore power connection anywhere in the world. From Barbados to St.Tropez, from Stavanger to Florida. No matter what the voltage and frequency on offer. Your Shoremaster will automatically provide the appropriate power to your on board equipment.
Supplying the power is only half the story because the Shoremaster also stabilizes and converts the incoming power for your safety and convenience. In the meantime it takes care of a safe separation between the shore power connection and on board circuits. Finally, it delivers high start-up power to counterbalance the peak load caused by the activation of air-conditioning and other equipment with a high initial power surge. All this is provided without annoying high-frequency noise.
This Shoremaster model is able to draw power from two separate shore connections, ensuring that your boat still runs at full capacity in the event of limited available shore power. With the single-phase input option the Shoremaster Compact can be used in marinas where a three-phase system is not available. In the case of a single-phase input, the output power is reduced to 60% of its nominal rating. |
Specifications
| INPUT SPECIFICATIONS |
| INPUT SPECIFICATIONS |
| Nominal input voltage |
208-480V |
| Nominal input voltage |
208-480V |
| Voltage window |
190-520V |
| Voltage window |
190-520V |
| Nominal input frequency |
50-60 Hz |
| Nominal input frequency |
50-60 Hz |
| Input frequency range |
40-70 Hz |
| Input frequency range |
40-70 Hz |
| Number of phases |
three phase + N |
| Number of phases |
three phase + N |
| Used current at 208V |
120 Amps |
| Used current at 208V |
120 Amps |
| Used current at 400V |
63 Amps |
| Used current at 400V |
63 Amps |
| Power factor (cos phi) |
>0.98 |
| Power factor (cos phi) |
>0.98 |
| OUTPUT SPECIFICATIONS |
| OUTPUT SPECIFICATIONS |
| Output voltage |
customer specified (any output voltage possible: e.g. 208, 380, 400, 440, 480 Volt) |
| Output voltage |
customer specified (any output voltage possible: e.g. 208, 380, 400, 440, 480 Volt) |
| Output frequency |
50 or 60 Hz |
| Output frequency |
3 |
| Number of phases |
3 |
| Number of phases |
<1% |
| Voltage tolerance |
<1% |
| Voltage tolerance |
50 or 60 Hz |
| Frequency tolerance |
<1% |
| Frequency tolerance |
<1% |
| Power |
40 kVA/32 kW |
| Power |
40 kVA/32 kW |
| Overload capability |
120% cont. at 25°C; 150% 60 sec.; 200% 10 sec. |
| Overload capability |
120% cont. at 25°C; 150% 60 sec.; 200% 10 sec. |
| Efficiency |
>90% |
| Efficiency |
<90% |
| Harmonic distortion (THD) on linear loads |
<1% |
| Harmonic distortion (THD) on linear loads |
<1% |
| EMC |
CE directives |
| EMC |
CE directives |
| Phase unbalance |
0-100% |
| Phase unbalance |
0-100% |
| Max. ambient temperature |
45°C |
| Max. ambient temperature |
45°C |
| Enclosure |
| ENCLOSURE |
| Dimensions (H x W x D) (indicative) |
1400 x 660 x 600 mm |
| Dimensions (H x W x D) (indicative) |
1400 x 660 x 600 mm |
| Weight (indicative) |
538 kg |
| Weight (indicative) |
538 kg |
| Protection degree |
IP23 |
| Protection degree |
IP23 |
| Cooling |
low noise fans |
| Cooling |
low noise fans |
| Material |
coated steel (all used materials are suitable for marine applications) |
| Material |
coated steel (all used materials are suitable for marine applications) |
| Readout |
digital LCD |
| Readout |
digital LCD |
| Communication |
ModBUS |
| Communication |
ModBUS |
| OPTIONAL |
| OPTIONAL |
| Single phase input |
yes |
| Single phase input |
yes |
| Classification Lloyd's ABS, DNV, BV, GL etc. |
yes |
| Classification Lloyd's ABS, DNV, BV, GL etc. |
yes |
| Dual input option |
yes |
| Dual input option |
yes |
| Parallel option |
yes |
| Parallel option |
yes |
| Auto startup option |
yes |
| Auto startup option |
yes |
| Commissioning |
upon request |
| Commissioning |
upon request |
Compare Shoremaster Compact 40
Accessories
| There are no accessories available. |
Downloads
Thank you for visiting www.mastervolt.com. To best view these downloads, we recommend Internet Explorer 7.0 or Firefox 3.
|
|