Meter Interface (MI)

AC

3 x AC voltage inputs (multi voltage).

2 x AC current inputs.

Calculates true RMS power.

DC

3 x DC voltage inputs (multi voltage).

2 x DC current inputs.

Calculates battery capacity as ampere hours

and percentage charge remaining.

Resolution for current metering down to

0.1 A.

GENERAL

Dimensions, hxwxd:

100 x 156 x 42 mm / 3.9 x 6.1 x 1.7 inch

IPx5 water ingress protection.

Outputs standard NMEA 2000 power

monitoring sentences.

Product code

80-911-0005-00

Meter Interface with

seal and plug

Product code

80-911-0006-00

Meter Interface only

CZONE

®

CZONE NETWORK COMPONENTS

Meter Interface (MI)

Output Interface (OI)

4 levels of backup fusing including manual

override (as required by ABYC).

Multiple channels can be bridged together to

offer higher current switching.

Power consumption 12 V: 85 mA (standby

60 mA).

Dimensions, hxwxd:

128 x 200 x 45 mm / 5 x 7.9 x 1.8 inch

Small, non-metallic, easy to install case.

IPx5 water ingress protection.

6 x 20 amps circuits.

Programmable software ‘fuse’ sizes.

Motor Output Interface (MOI)

Single motor control and two normal

channels per unit, 20 A per output.

Built-in circuit protection.

IPx5 water ingress protection.

Dimensions, hxwxd:

128 x 200 x 45 mm / 5 x 7.9 x 1.8 inch

Product code

80-911-0009-00

Output Interface

with connector and

protective boot

Product code

80-911-0007-00

Motor Output Interface

with connector and

protective boot

Product code

80-911-0010-00

Output Interface only

Product code

80-911-0008-00

Motor Output Interface

only

Output Interface (OI)

Motor Output Interface

(MOI)

Fuses for emergency circuit bypass.

Network status indicator.

NMEA 2000 connector.

Connector and protective boot.

3

1

4

2

The Motor Output Interface has an

output pair for controlling DC motors

which require a reversal of polarity to

change the direction of their mechanical

operation. For example, a DC motor for

an electric window mechanism will move

the window up or down depending on

the polarity of the feed to the motor.

The MOI also incorporates two standard

output channels as found on the Output

Interface (OI).

The Output Interface provides an

intelligent replacement for traditional

circuit breaker and fuse panels. It has

six high power, robust output channels

which provide the power supply,

control and fusing for a circuit as well as

integrating many other features such as

timers and dimmers. Connection to the

unit is simple: a large 6-way plug allows

connections to cables of up to

16 mm

2

(6AWG) in size, or multiple

smaller conductors. No need for

specialised crimp terminals and

expensive crimp tools to be carried

for terminations to CZone, just a blade

screwdriver. A protective flexible boot

offers protection to the connections

from harsh environment conditions.

The Meter Interface accepts inputs from

external AC and DC power metering

sensors such as: AC and DC voltage and

amps, AC kWatts, and DC battery capacity

in amp hours and % remaining. All with

user definable high and low alarms.