Mass GI 3.5

Mass GI 7

IVET 3.5

IVET 4.5

IVET 6

Product code

88000355

88000705

85000350

85000450

8500060

Product code with casing

n.a.

n.a.

n.a.

n.a.

n.a.

INPUT

Input voltage

90-255 V

90-255 V

110/220/240 V

110/220/240 V

110/220/240 V

Input frequency

45-65 Hz

45-65 Hz

45-65 Hz

45-65 Hz

45-65 Hz

Nominal input current at 230 V

16 A

32 A

16 A

20 A

26 A

No-load consumption

22 W

44 W

<10 W

<10 W

<10 W

Earth leakage protection

no

no

no

no

no

OUTPUT

Output voltage (equal to input)

90-255 V, ± 5 %

90-255 V, ± 5 %

120/220/240 V, ± 5 % 120/220/240 V, ± 5 % 120/220/240 V, ± 5 %

Output frequency

equal to input

equal to input

equal to input

equal to input

equal to input

Soft Start

yes

yes

option

option

option

Switch off behaviour breaker

B-characteristic

B-characteristic

n.a.

n.a.

n.a.

Efficiency

> 93 %

> 93 %

> 93 %

> 93 %

> 93 %

GENERAL SPECIFICATIONS

Power

3500 W (up to 4 units

parallel = 14 kW)

7000 W

3500 W

4500 W

6000 W

Technology

high frequency

high frequency

E-core

E-core

E-core

Dimensions, hxwxd

340 x 261 x 144 mm

13.4 x 10.3 x 5.7 inch

340 x 261 x 250 mm

13.4 x 10.3 x 9.8 inch

330 x 200 x 185 mm

13 x 7.9 x 7.3 inch

330 x 240 x 185 mm

13 x 9.4 x 7.3 inch

380 x 240 x 215 mm

15 x 9.5 x 8.5 inch

Weight

6 kg / 13.2 lb

10 kg / 22 lb

30 kg / 66.1 lb

53 kg / 77.2 lb

49 kg / 108 lb

Approvals

CE, ABYC

CE, ABYC

CE, ABYC

CE, ABYC

CE, ABYC

Ambient temperature

0 °C to 40 °C,

derating power > 40 °C

0 °C to 40 °C,

derating power > 40 °C

0 °C to 40 °C,

derating power > 40 °C

0 °C to 40 °C,

derating power > 40 °C

0 °C to 40 °C,

derating power > 40 °C

Switch off at

80 °C

80 °C

n.a.

n.a.

n.a.

Cooling

variofan

variofan

natural cooling

natural cooling

natural cooling

Operating humidity

max. 95 %

max. 95 %

max. 95 %

max. 95 %

max. 95 %

Protection degree

IP23

IP23

IP00

IP00

IP00

MasterBus compatible

yes

yes

no

no

no

Specifications

Isolation

Transformers

6 kVA

9 kVA

13 kVA

Soft Start

13 kVA

Soft Start

22 kVA

Product code

55010600

55010900

55011300

55003300

55003400

Voltage

120/230 V

120/230 V

120/230 V

230 V

230 V

Power

6 kW

9 kW

13 kW

2.5-13 kW

13-22 kW

Max. input current

60 A at 120 V

30 A at 230 V

80 A at 120 V

40 A at 230 V

130 A at 120 V

70 A at 230 V

n.a.

n.a.

Dimensions, hxwxd

400 x 300 x 210 mm

15.7 x 11.8 x 8.3 inch

400 x 300 x 210 mm

15.7 x 11.8 x 8.3 inch

400 x 300 x 210 mm

15.7 x 11.8 x 8.3 inch

200 x 180 x 115 mm

7.9 x 7.1 x 4.5 inch

200 x 180 x 115 mm

7.9 x 7.1 x 4.5 inch

Weight

12 kg / 26.5 lb

12.5 kg / 27.6 lb

13 kg / 28.7 lb

1.2 kg / 2.6 lb

1.5 kg / 3.3 lb

Specifications

Transfer systems

with Soft Start and

automatic detection

of the input voltage

OPTIONS

EasyView 5

77010310

option

option

n.a.

n.a.

n.a.

Waterproof system monitor with ‘daylight readable’ colour display and intuitive multi-language touchscreen to show the key system information at a glance.

There is also a logbook feature for warnings and alarms, along with a buzzer and alarm notifications. The home button gives access to favorite pages.

Soft Start 13 kW

55003300

included

included

option

option

option

Automatic switch that suppresses the inrush current from the isolation transformer to prevent the shore power fuse from blowing.

Soft Start 22 kW

55003400

included

included

n.a.

n.a.

n.a.

Automatic switch that suppresses the inrush current from the isolation transformer to prevent the shore power fuse from blowing.