Table of Contents Table of Contents
Previous Page  16 / 268 Next Page
Information
Show Menu
Previous Page 16 / 268 Next Page
Page Background

Mass

Mass

Mass

Mass

24/15-2

24/25-2

24/25-2 DNV

24/50-2

Product code

40020156

40020256

40720266

40020506

Product code 120 V

GENERAL SPECIFICATIONS

Nominal output voltage

24 V

24 V

24 V

24 V

Total charge current

15 A at 28.5 V

25 A at 28.5 V

25 A at 28.5 V

50 A at 28.5 V

Number of battery outlets

2

2

2

2

Charge current second output

3 A

3 A

3 A

3 A

Recommended battery capacity

30-150 Ah

50-250 Ah

50-250 Ah

100-500 Ah

Nominal input voltage

230 V (180-265 V)

- 50/60 Hz

230 V (180-265 V)

- 50/60 Hz

230 V (180-265 V)

- 50/60 Hz

230 V (180-265 V)

- 50/60 Hz

Power supply mode

yes

yes

yes

yes

Display/read-out

LED display

LED display

LED display

LED display

Dimensions, hxwxd

325 x 220 x 111 mm

12.8 x 8.7 x 4.4 inch

325 x 220 x 111 mm

12.8 x 8.7 x 4.4 inch

365 x 220 x 111 mm

14.4 x 8.7 x 4.4 inch

340 x 261 x 130 mm

13.4 x 10.3 x 5.1 inch

Weight

3.3 kg / 7.3 lb

3.3 kg / 7.3 lb

3,5 kg / 7.7 lb

4.6 kg / 10.1 lb

Approvals

CE, ABYC A-31, RRR, RMRS CE, ABYC A-31, RRR, RMRS CE, ABYC A-31, DNV, RRR,

RMRS

CE, ABYC A-31, DNV, RRR,

RMRS

TECHNICAL SPECIFICATIONS

Charge characteristic

Charge characteristic can be set to your requirements.

See page 242 for default settings.

IUoUo, automatic /

3-step+ for Gel/AGM/

flooded/Lithium Ion

IUoUo, automatic /

3-step+ for Gel/AGM/

flooded/Lithium Ion

IUoUo, automatic /

3-step+ for Gel/AGM/

flooded/Lithium Ion

IUoUo, automatic /

3-step+ for Gel/AGM/

flooded/Lithium Ion

Temperature sensor

yes (included)

yes (included)

yes (included)

yes (included)

DC voltage drop compensation

yes

yes

yes

yes

DC consumption

< 1 mA

< 1 mA

< 1 mA

< 1 mA

Full load consumption (230 V AC)

550 W

880 W

880 W

1800 W

Power factor control

> 0.95

> 0.95

> 0.95

> 0.95

Temperature range (ambient temp.)

-25 °C to 80 °C;

> 45 °C derating power

-25 °C to 80 °C;

> 45 °C derating power

-25 °C to 80 °C;

> 45 °C derating power

-25 °C to 80 °C;

> 45 °C derating power

Cooling

vario fan

vario fan

vario fan

vario fan

Protection degree

IP23

IP23

IP23

IP23

Protections

over-temperature,

overload, short circuit,

high/low battery voltage

over-temperature,

overload, short circuit,

high/low battery voltage

over-temperature,

overload, short circuit,

high/low battery voltage

over-temperature,

overload, short circuit,

high/low battery voltage

MasterBus compatible

yes

yes

yes

yes

Charger Status Interface (alarm contact)

yes

yes

yes

yes

PRODUCTS

|

CHARGE & CONVERT

Specifications

Mass battery

chargers

OPTIONS

MasterView Read-out

77010050

option

option

option

option

Remote panel for reading the charge status of your battery charger, including error notifications.

EasyView 5

77010310

option

option

option

option

Waterproof system monitor with ‘daylight readable’ colour display and intuitive multi-language touchscreen to show the key system information at a glance.

There is also a logbook feature for warnings and alarms, along with a buzzer and alarm notifications. The home button gives access to favorite pages.

MasterShunt

77020110

option

option

option

option

MasterBus integrated battery monitor, with detailed information on the status of your batteries for an optimised charging process, incl. voltage, current,

remaining time and consumption capacity in percentage.

DC Distribution

77020200

option

option

option

option

Smallest distribution model available. It connects up to four DC devices to the DC groups, such as a battery charger, inverter, alternators and solar panels.

With the included plug & play cable it can be easily connected to the MasterBus network.

MasterBus USB Interface

77030100

option

option

option

option

Communication port between MasterBus and the USB port of your PC; enables reading and configuration of your MasterBus system on the PC when

combined with MasterAdjust software (free to download).

MasterVision panels

C3-RS

70403040

option

option

option

option

Remote monitor for battery chargers, with a regulator for reducing grid power consumption.

GMDSS remote panel

70400050

option

option

option

option

Remote monitoring for Mass battery chargers, with GMDSS system monitoring functions. Battery voltage and current are displayed on the digital panel.