Table of Contents Table of Contents
Previous Page  32 / 268 Next Page
Information
Show Menu
Previous Page 32 / 268 Next Page
Page Background

OPTIONS

C4-RI

70404110

option

option

option

option

Remote control on/off for the Mass Sine sine wave inverter.

EasyView 5

77010310

option

option

option

option

In combination with MasterBus Inverter Interface. Waterproof system monitor with ‘daylight readable’ colour display and intuitive multi-language touchscreen

to show the key system information at a glance. There is also a logbook feature for warnings and alarms, along with a buzzer and alarm notifications. The

home button gives access to favorite pages.

MasterBus USB Interface

77030100

option

option

option

option

In combination with MasterBus Inverter Interface. Communication port between MasterBus and the USB port of your PC; makes possible reading and

configuration of your MasterBus system on the PC when combined with MasterAdjust software (free to download).

MasterBus Inverter Interface

77030700

option

option

option

option

Integrates the Mass Sine inverter in a MasterBus network.

AC Power Analyser

77031200

option

option

option

option

Integrates the Mass Sine inverter in a MasterBus network and visualizes the AC voltage, current and power.

Mass Sine

Mass Sine

Mass Sine

Mass Sine

12/2000

24/800

24/1500

24/2500

Product code 230 V

24012000

24020800

24021500

24022500

Product code 230 V 60 Hz

24112000

24120800

24121500

24122500

GENERAL SPECIFICATIONS

Nominal battery voltage

12 V

24 V

24 V

24 V

Recommended battery capacity

> 200 Ah

> 50 Ah

> 150 Ah

> 200 Ah

Output voltage

230 V (± 5 %) –

50 Hz (± 0.01 Hz)

230 V (± 5 %) –

50 Hz (± 0.01 Hz)

230 V (± 5 %) –

50 Hz (± 0.01 Hz)

230 V (± 5 %) –

50 Hz (± 0.01 Hz)

P30 power at 40 °C, cos phi 1

2000 W

800 W

1500 W

2500 W

Continuous power at 40 °C, cos phi 1

1800 W

650 W

1200 W

2000 W

Peak load

4000 W

1600 W

2900 W

5000 W

Output waveform

true sine

true sine

true sine

true sine

AC connection

internal

internal

internal

internal

Efficiency

92 %

92 %

92 %

92 %

Display/read-out

LED display

LED display

LED display

LED display

Parallel configuration

no

no

no

no

3-Phase configuration

no

no

no

no

Dimensions, hxwxd

420 x 318 x 136 mm

16.5 x 12.5 x 5.4 inch

325 x 220 x 111 mm

12.8 x 8.7 x 4.4 inch

340 x 261 x 130 mm

13.4 x 10.3 x 5.1 inch

420 x 318 x 130 mm

16.5 x 12.5 x 5.1 inch

Weight

14.6 kg / 32.2 lb

3.9 kg / 8.6 lb

8 kg / 17.4 lb

14.6 kg / 32.2 lb

Approvals

CE, E-mark, ABYC A-31

CE, E-mark, ABYC A-31

CE, E-mark, ABYC A-31

CE, E-mark, ABYC A-31

TECHNICAL SPECIFICATIONS

Technology

HF switch mode

HF switch mode

HF switch mode

HF switch mode

Max. ripple on DC (battery)

5 % RMS

5 % RMS

5 % RMS

5 % RMS

Input current (nominal load)

183 A

36 A

68 A

115 A

No-load power consumption (ON mode)

480 mA – 6 W

240 mA – 5.6 W

200 mA – 5 W

250 mA – 6 W

No-load power consumption (energy saving mode)

50 mA – 0.6 W

35 mA – 0.8 W

25 mA – 0.6 W

25 mA – 0.6 W

Minimal DC fuse (slow blow)

DC fuse depends on the cable size

250 A

63 A

100 A

160 A

Minimal cable size

70 mm

2

16 mm

2

25 mm

2

50 mm

2

Harmonic distortion typical

< 5 %

< 5 %

< 5 %

< 5 %

Power factor control

all power factors allowed all power factors allowed all power factors allowed all power factors allowed

Transfer system

Masterswitch/Systemswitch

compatible, see page 128

for more information

Masterswitch/Systemswitch

compatible, see page 128

for more information

Masterswitch/Systemswitch

compatible, see page 128

for more information

Masterswitch/Systemswitch

compatible, see page 128

for more information

Temperature range (ambient temp.)

-25 °C to 80 °C;

> 40 °C derating

-25 °C to 80 °C;

> 40 °C derating

-25 °C to 80 °C;

> 40 °C derating

-25 °C to 80 °C;

> 40 °C derating

Cooling

natural/forced

natural/forced

natural/forced

natural/forced

Protection degree

IP23

IP23

IP23

IP23

Protections

over-temperature,

overload, short circuit,

high battery, low battery

over-temperature,

overload, short circuit,

high battery, low battery

over-temperature,

overload, short circuit,

high battery, low battery

over-temperature,

overload, short circuit,

high battery, low battery

MasterBus compatible

yes, using a MasterBus

Inverter Interface or

AC Power Analyser

yes, using a MasterBus

Inverter Interface or

AC Power Analyser

yes, using a MasterBus

Inverter Interface or

AC Power Analyser

yes, using a MasterBus

Inverter Interface or

AC Power Analyser

PRODUCTS

|

CHARGE & CONVERT

Specifications

Mass Sine (Ultra)

sine wave inverters

32