AC Master

AC Master

AC Master

AC Master

24/300

24/500

24/700

24/1000

Product code

28020300

28020500

28020700

28021000

With UK plug

n.a.

n.a.

28220700

28221000

With NZ/AU plug

n.a.

n.a.

28420700

28421000

GENERAL SPECIFICATIONS

Output voltage

230 V – 50 Hz (± 0,1.%)

230 V – 50 Hz (± 0,1.%)

200/220/230/240 V

50/60 Hz (selectable)

200/220/230/240 V

50/60 Hz (selectable)

Output waveform

true sine

true sine

true sine

true sine

Nominal battery voltage

24 V

24 V

24 V

24 V

Recommended battery capacity

≥ 30 Ah

≥ 50 Ah

≥ 50 Ah

≥ 65 Ah

Continuous power at 25 °C / 77 °F, cos phi 1

300 W

500 W

700 W

1000 W

Continuous power at 40 °C / 104 °F, cos phi 1

250 W

400 W

700 W

1000 W

Peak load

600 W

800 W

< 810 W (1 min.)

< 1230 W (1 sec.)

< 1150 W (1 min.)

< 1750 W (1 sec.)

AC connection

universal

universal

plug connection EU

(Schuko) or UK

plug connection EU

(Schuko) or UK

Efficiency

91 %

91 %

93 %

94 %

Parallel configuration

n.a.

n.a.

n.a.

n.a.

3-Phase configuration

n.a.

n.a.

n.a.

n.a.

Display/read-out

LED display

LED display

LED indication: battery

voltage, load level, status

LED indication: battery

voltage, load level, status

Dimensions, hxwxd

210 x 130 x 60 mm

8.3 x 5.1 x 2.4 inch

210 x 130 x 60 mm

8.3 x 5.1 x 2.4 inch

200 x 330 x 83 mm

7.9 x 13 x 3.3 inch

200 x 372 x 83 mm

7.9 x 14.6 x 3.3 inch

Weight

1,16 kg / 2.55 lb

1,22 kg / 2.69 lb

2,7 kg / 6 lb

3,3 kg / 7.3 lb

Alarms

4 alarm modes

4 alarm modes

potential free alarm contact potential free alarm contact

Approvals

CE, E-mark, ABYC A-31

CE, E-mark, ABYC A-31

CE, E-mark, RCM

CE, E-mark, RCM

TECHNICAL SPECIFICATIONS

Technology

high frequency, input &

output fully isolated

high frequency, input &

output fully isolated

high frequency, input &

output fully isolated

high frequency, input &

output fully isolated

Input current (nominal load)

11 A

19 A

35 A

50 A

No-load power consumption (energy saving mode)

0.16 A – 4 W

0.16 A – 4 W

< 0.06 A

< 0.05 A

Minimal DC fuse (slow blow)

40 A

40 A

50 A

63 A

Minimal cable size

1.5 mtr DC cable delivered

as standard

1.5 mtr DC cable delivered

as standard

16 mm

2

16 mm

2

Harmonic distortion typical

< 6 %

< 6 %

< 5 %

< 5 %

Cos phi

all power factors allowed

all power factors allowed

all power factors allowed

all power factors allowed

Transfer system

n.a.

n.a.

n.a.

n.a.

Temperature range (ambient temp.)

0 °C to 40 °C, derating

power > 40 °C

0 °C to 40 °C, derating

power > 40 °C

-20 °C to 40 °C, derating

power > 40 °C

-20 °C to 40 °C, derating

power > 40 °C

Protection degree

IP23, vertical wall mounting IP23, vertical wall mounting IP21, horizontal wall

mounting

IP21, horizontal wall

mounting

Protections

over-temperature, over

load, short circuit, high/low

battery voltage

over-temperature, over

load, short circuit, high/low

battery voltage

over-temperature, overload,

short circuit, high/low

voltage, reverse polarity

(fuse)

over-temperature, overload,

short circuit, high/low

voltage, reverse polarity

(fuse)

Cooling

natural/forced

natural/forced

temperature and load

controlled fan

temperature and load

controlled fan

MasterBus compatible

no

no

no

no

Specifications

AC Master

sine wave inverters

24 V

PRODUCTS

|

CHARGE & CONVERT

OPTION

Inverter Control Panel (ICP)

70405080

n.a.

n.a.

option

option

On/off control for the AC Master sine wave inverter with a clear on/off indicator which indicates when the inverter is active. In addition, the ICP makes it

possible to turn the inverter on or off automatically by means of a 12-volt input, for example when switching on the onboard AC power or while starting an

engine. The ICP remote control comes with 8 m (25 ft) cable.