Table of Contents Table of Contents
Previous Page  84 / 268 Next Page
Information
Show Menu
Previous Page 84 / 268 Next Page
Page Background

MasterShunt 500

Product code

77020110

Dimensions, hxwxd

150 x 150 x 65 mm

5.9 x 5.9 x 2.5 inch

Weight

0.7 kg / 1.54 lb

Battery types

Gel, AGM, flooded, Lithium Ion

Battery voltage

12, 24 or 48 V DC

Current

300 A continuously, 400 A for 10 min.,

500 A for 5 min. and 600 A for 2 min.

MasterBus powering

yes, incl. Smart MasterBus Powering

Idle consumption

23 mA (normal operation), <1 mA (power

saving, MasterBus off)

System functionality

alarm, timers, auto start/stop for the

generator

System information

e.g. time remaining, voltage, current,

state of charge

Programmable alarms

warning low voltage, warning low state of

charge, high voltage

Protection degree

IP21

Main fuse

bus bar included in MasterShunt, Class T

fuse or ANL fuse to be ordered separately

Delivered with

MasterShunt, temperature sensor,

MasterBus terminator, MasterBus cable,

isolation cover for DC connections

MORE INFORMATION

MASTERVOLT.COM/MASTERBUS

PRODUCTS

|

MANAGE & MONITOR

MasterShunt 500

RENEWED

MODEL

MasterShunt is the heart of every MasterBus energy system.

This integrated battery monitor shares information about the

battery bank with other Mastervolt devices such as battery

chargers, Combis, and displays. No surprises: allowing complete

automation of your system, MasterShunt improves comfort,

prolongs battery life and extends your runtime.

The MasterShunt 500 provides all information needed for monitoring

your battery bank and control of your system, such as voltage,

current, state of charge and time remaining. All information is made

available to the system by a single MasterBus cable. Extremely

accurate measurement of current flow over state of charge enables the

MasterShunt to precisely determine the time remaining.

Programmable events and an integrated real time clock make it possible

to fully automate your system. Examples are to start your generator

automatically when the battery bank is low (or just delaying at night!), or

to automatically generate a warning at a certain depth of discharge.

The proven MasterShunt design has been upgraded to obtain an even

higher level of accuracy and control. Taking into account battery specific

parameters, MasterShunt takes reading accuracy to a whole new level.

MasterBus Network Components

A new service mode prevents loss of valuable informa-

tion, such as the state of charge, during system main-

tenance. A maximum Depth of Discharge (DOD) can be

set and time remaining will be adjusted accordingly.

The renewed MasterShunt allows freedom of choice

with regards to fuse type, rating and location. The

battery monitor is supplied with an internal bus bar, to

be used in situations where an external fuse holder is

selected. In case the MasterShunt is installed close to

the battery, the bus bar may be replaced by either an

ANL type or Class T main fuse, saving both space and

cost.

n

Digital shunt providing the energy system with extensive

information and historical data.

n

Very accurate and reliable determination of State of Charge

(SOC).

n

Easy connection to all MasterBus devices.

n

Power saving mode for reduced idle consumption.

n

Service mode prevents memory loss during system

maintenance.

n

Realistic and precise indication of the time remaining.

n

Smart MasterBus powering mode reduces idle consumption

to a bare minimum.

n

For higher current, multiple MasterShunt models may be

installed in parallel.

n

MasterConnect system makes connecting to the DC

Distribution product very easy.

n

Straight forward, easy to install.

n

Freedom of choice for fuse type, rating and location.

Suitable for T-fuse and ANL-fuse (to be ordered separately).

n

Robust housing with isolation of the DC connections.

FEATURES

NEW

SYSTEM

CONTROL

84