MASTERBUS NETWORK COMPONENTS

MASTERSHUNT 500

DC DISTRIBUTION 500

DIGITAL DC 10X10A

DC Distribution 500

The DC Distribution 500 is the smallest distribution model

available. It connects up to four DC devices, such as a

battery charger, inverter, alternators and solar panels.

With the plug & play cable it can be easily connected to

the MasterBus network. The EasyView panel gives all fuses

logical names, for instance, referring to the connected

equipment, to ensure you receive understandable error

notifications (for example: battery charger fuse defect).

Digital DC 10x10A

As the pinnacle of system intelligence, the Mastervolt Digital

DC 10x10A has ten 10 A outputs for all functions including

lighting, pumps, electronics, etc. It comes standard with

intelligent alarm functions and luxury options include:

n

Follow me home (light stays on for a specific time).

n

Delayed dimming of lights (including ten built-in

dimmers).

n

Alarm signal for overload.

n

Every output has a hardware and software fuse.

n

Reset the fuses via the MasterBus network.

n

Possibility of higher currents (up to 100 A) with parallel

switching of multiple outputs.

n

Logical Blocks.

DC Distribution 500

Product code

77020200

Dimensions, hxwxd

150 x 216 x 65 mm

5.9 x 7.9 x 2.5 inch

Weight

1.2 kg / 2.6 lb

Battery voltage

12, 24 or 48 V DC

Current

300 A continuous /

500 A for 5 minutes

MasterBus powering

no

Standard fuses

80 A (2x), 160 A and 125 A - ANL type (deviating

values can be ordered separately)

Spare fuse

125 A - ANL type

Alarm

fuse monitoring

Protection degree

IP21

Delivered with

four standard fuses and one spare fuse, hex tool,

MasterBus terminator, MasterBus cable, cable

protections for DC connections

Digital DC 10x10A

Product code

77020400

Dimensions, hxwxd

40 x 229 x 110 mm

1.6 x 9.0 x 4.3 inch

Weight

750 gr / 1.7 lb

MasterBus powering

yes

Power consumption

< 2 mA at 12/24 V

Protection degree

IP21

DC OUTPUT

Connection

cable max. 4 mm²

Maximum software

fuse current

10 A per channel

Hardware fuse

current

15 A per channel

DC INPUT

Connections

max. 95 mm² or directly connected to

MasterShunt or DC Distribution

Maximum current

100 A

Supply voltage

8-30 V DC