Page Background

V - A

ALARMS FOR MASS BATTERY CHARGERS

MASS CHARGER INTERFACE

n

Battery – DC voltage

n

Battery – charge/discharge current

n

Battery charger – output voltage

n

Battery charger – output current

Operating principle:

DC LOW/HIGH ALARM

CHARGER FAILURE INDICATION

CHARGER MAINS STATUS

AUDIO ALARM

SILENCE

For professional use: GMDSS

For the professional user, there is a front

display with alarm functions according to

GMDSS available. The GMDSS (“Global

Maritime Distress and Safety System”)

is a global maritime communication

system which is part of SOLAS (Safety

Of Life At Sea), using DSC and satellite

communications.

Mass Charger Interface

Every Mass battery charger can be equipped with an intelligent front panel.

The Mass Charger Interface combines the following functions:

n

LCD display:

DC voltage and charge/discharge

current.

n

Alarm functions:

DC high/low voltage alarm

visual/acoustic and potential-free contact.

n

Alarm functions:

AC alarm, no input voltage AC

visual/acoustic and potential-free contact.

n

CSI alarm:

Charger Status Interface, charger error

visual/acoustic and potential-free contact.

The Mass Charger Interface makes your Mass

battery charger suitable as a power supply/battery

charger for devices such as GMDSS emergency

systems for seagoing vessels and yachts. The alarm

settings, charge current and charging method can

easily be adapted using the LCD display and control

button, and the front display can be easily and

quickly installed on the charger. The Mass Charger

Interface is optional and is delivered complete with

shunt and detailed manual. The battery charger

needs to be separately ordered.