Alarms for ChargeMaster battery chargers

The ChargeMaster 12/35-3, 12/50-3,

24/20-3 and 24/30-3 are equipped

with simple alarms using LEDs on

the front panels.

Above models are protected against

overload, short circuit, over heating

and under and over voltage. If a fault

condition occurs, a load bar segment

on the display illuminates red. The LED

position indicates the failure cause.

* The

POWER

button is blinking.

** At ‘

Battery low

’ the battery

bank number concerned is

blinking. Selecting another

bank is still possible then,

the display will return after

5 seconds.

LOAD BAR FAULT CONDITION

Wrong AC voltage*

Charger failure*

Battery voltage too high*

Internal temperature too high*

Battery low, short circuit**

Blinking: AC not available

The larger models such as the

ChargeMaster 12/70-3, 12/100-

3, 24/40-3, 24/60-3, 24/80-3 and

24/100-3, use the digital front panel

of the battery charger for error

notifications.

Should an error occur,

FAILURE

is shown

on the display. The origin of the error is

displayed by means of an error code.

ERROR CODE

FAULT CONDITION

INP FREQ

AC Input frequency too high or too low

INP VOLT

AC Input voltage too high or too low

HIGH VOLT

Battery voltage too high

LOW VOLT

Battery voltage too low

BATT LOW

Battery voltage too low

TMP SD

Temperature shutdown

In general, error codes indicate

problems with the wiring,

fuses or a poor grid quality.

Check these thoroughly before

contacting your installer or

supplier.