Table of Contents Table of Contents
Previous Page  103 / 268 Next Page
Information
Show Menu
Previous Page 103 / 268 Next Page
Page Background

CZONE

®

CZONE NETWORK COMPONENTS

AC Mains Interface (ACMI)

A sophisticated source selector or transfer switch, the

AC Mains Interface enables the user to specify the AC

power source (generator, inverter, mains).

Developed for use with the CZone digital control

system, but may also be used as a stand-alone device.

The ACMI can be programmed to automatically change the

supply source when the current rating is exceeded, and

includes a manual override and user-friendly display screen

that ensures easy current, voltage, frequency, and power

monitoring. Other features include six monitored, over-current

protected main power inputs of up to 100 A each, as well as two

outputs, which enables two separate load groups and a parallel

option for use with a single source. To simplify installation, the

ACMI comes pre-wired.

MORE INFORMATION

MASTERVOLT.COM/CZONE

ACMI standard

Three inputs: 1 x 16 A mains, 1 x 32 A mains,

1 x 50 A generator parallel.

Two load groups: 40 A.

230 V AC 50 Hz.

Current, voltage, frequency and power

monitoring incorporated.

Manual override panel on enclosure.

Dimensions, hxwxd:

430 x 540 x 186 mm / 17 x 21.3 x 7.3 inch

n

Six source inputs up to 100 A (e.g. 2 x mains, 2 x generator).

n

Monitoring of channel status (on/off/fault).

n

Provides circuit protection and control.

n

Manual override at enclosure and via remote panel.

n

Customizable to suit installation requirements.

n

Supports multiple pole designs, i.e. double, triple, four pole.

n

110 V, 240 V, 110/220 V.

n

IPx5 enclosure.

n

Utilizes standard DIN rail mounted components for circuit

protection and control.

n

Current, voltage, frequency and power monitoring

incorporated (six channels).

n

Physical and software lockouts between source controls

(prevents two sources from becoming connected).

n

Reverse polarity and bad power supply alarms including

auto disconnect and lockouts.

n

Two outputs (load groups), allows for two separate load

groups with parallel option for use with single source.

n

Auto changeover.

n

Provision for RCD’s.

n

Load shedding.

n

Status LEDs at enclosure.

n

Pre-wired for quick connection.

n

Timer controls.

n

50 or 60 Hz.

Product code

80-911-0068-00

For quotation purposes only, contact

Mastervolt for custom requirements.

FEATURES

Sample AC mains screen.

103